Enjoy everyday hot and cold water alongside reverse osmosis filtered drinking water, all from one premium kitchen mixer. No separate drinking water tap required.

HotFrom your hot water system, unchanged
ColdNormal cold water, unchanged
ROIts own internal channel, fed from the under-sink system
At the benchOne 3-way mixerHot and cold mix as normal. RO water keeps its own channel.
A diagram of the water paths, not a product photograph. Photographs are added once the tap is approved.

ProposedRO Compact and RO Plus are planned options. The supplier, components, compliance and installed price are still being confirmed, so nothing here is available for immediate installation. You can request a quote or register interest now.

How reverse osmosis works

Four stages, under the sink.

Mains pressure pushes water through a membrane far finer than any cartridge. Pretreatment protects that membrane, and a pressure tank stores what it makes so a glass fills at once.

  1. Sediment

    Catches particles first, so they do not foul the carbon or the membrane surface.

  2. Carbon

    Takes out chlorine before the membrane. Chlorine degrades the polyamide layer a membrane relies on.

  3. Membrane

    Mains pressure pushes water through a dense semi-permeable layer. Most dissolved salts stay behind and are rinsed to drain.

  4. Storage and polish

    Filtered water collects in a pressure tank, then passes any post-treatment on its way to the tap.

  1. Cold supplyIsolation valve on the cold line under the sink
  2. SedimentParticle pretreatment
  3. CarbonChlorine pretreatment
  4. RO membraneSeparates filtered water from concentrateConcentrate to drain
  5. Storage tank8 L or 16 L nominal, pressurised
  6. Post-treatmentFitted where required
  7. 3-way tapDedicated RO channel

A typical tank-fed layout. The stages in the system we supply are confirmed with the selected unit.

One tap, three waters

Hot, cold and RO. Kept apart.

The 3-way mixer takes the place of your existing kitchen tap. Hot and cold work as they do today, and RO drinking water has a separate control and its own waterway inside the tap.

Normal hot and cold
The main lever mixes hot and cold exactly as your current kitchen mixer does.
Separate RO control
A second control dispenses drinking water. It does not pass through the hot and cold mixing chamber.
Dedicated internal channel
RO water has its own waterway and outlet path inside the tap, so it does not blend with untreated water.
No second tap
The 3-way mixer takes the place of your existing mixer. Where your kitchen suits, no extra benchtop hole is needed.

Two proposed options

Eight litres, or sixteen.

Both use the same core filtration. The difference is the nominal size of the storage tank, and how much room it needs under the sink.

Option A

8 Lnominal tank

Home Water RO Compact

For smaller households, or kitchens with limited space under the sink.

  • Under-sink reverse osmosis system
  • 8 L nominal pressure storage tank
  • Sediment and carbon pretreatment
  • Reverse osmosis membrane
  • Post-treatment where required
  • Compatible 3-way mixer tap, with normal hot and cold kept
Request a quote for RO Compact

Option B

16 Lnominal tank

Home Water RO Plus

For households that prefer more stored drinking water between refills.

  • Under-sink reverse osmosis system
  • 16 L nominal pressure storage tank
  • The same core filtration technology as Compact
  • Greater nominal storage capacity
  • Needs more cabinet space for the tank
  • Compatible 3-way mixer tap, with normal hot and cold kept
Request a quote for RO Plus
RO Compact and RO Plus compared
FeatureRO CompactRO Plus
Reverse osmosisYesYes
Nominal tank size8 L16 L
Under-sink installationYesYes
3-way hot, cold and RO tapOptional or bundledOptional or bundled
Replacement cartridgesRequiredRequired
Fully installed priceTo be confirmedTo be confirmed

The installed price is published once installation costs are approved. Your specialist confirms a price in writing.

Storage is not production

How much it holds. How fast it makes.

Three different things decide how an RO system feels to live with. A larger tank does not make water any faster, and a faster membrane does not make a tank any larger.

Storage capacity
How much filtered water the tank can hold. A tank's nominal size is the vessel, not the water you can draw from it.
Production capacity
How quickly the membrane makes filtered water. It sets how long an emptied tank takes to refill.
Tap delivery
How quickly stored water comes out of the tap. Tank pressure drives it, so flow eases as the tank empties.
Nominal membrane production examples
Membrane ratingPer dayPer hour
50 GPD189 L/dayAbout 8 L/hour
100 GPD379 L/dayAbout 16 L/hour

GPD is US gallons per day. These are theoretical nominal rates under specified test conditions, not guaranteed household delivery. Actual output depends on feed pressure, temperature, water quality, membrane condition and tank back-pressure. If the selected unit has a different rated capacity, its verified specification is used instead.

The water, in numbers

What your feed water does to a membrane.

Reverse osmosis performance is set by the water going in. These are the parameters a specialist looks at, the usual reference for each, and why it matters.

Feed water parameters that affect reverse osmosis
ParameterReferenceWhy it matters for RO
Total dissolved solidsUp to 600 mg/L is regarded as good quality drinking water (ADWG, palatability)Sets the osmotic pressure the membrane has to overcome: roughly 7 kPa (1 psi) for every 100 mg/L.
Hardness, as calcium carbonate60 to 200 mg/L is good quality; above 200 mg/L scale increases (ADWG)Calcium carbonate can scale the membrane as the water beside it is concentrated. Hard feed water may need pretreatment.
Free chlorineHealth guideline 5 mg/L (ADWG); tap levels are normally far lowerOxidises thin-film polyamide membranes, which is why carbon sits ahead of the membrane. Chloramine is slower to remove, so carbon selection matters.
pH6.5 to 8.5 (ADWG, aesthetic)Affects scaling tendency. RO water often reads slightly below neutral, because dissolved carbon dioxide passes the membrane while alkalinity is held back.
TemperatureMembranes are commonly rated at 25 °CCold water is more viscous. Output falls by roughly 3 percent for each degree below the rating temperature.
Feed pressureMembranes are commonly rated at about 345 to 415 kPa (50 to 60 psi); AS/NZS 3500.1 limits static pressure at outlets to 500 kPaPressure is what moves water across the membrane. Low pressure means slower production and more water to drain.
Turbidity5 NTU (ADWG, aesthetic)Suspended particles foul the membrane surface. Sediment pretreatment is there to protect it.
Iron and manganeseIron 0.3 mg/L, manganese 0.1 mg/L (ADWG, aesthetic)Both can foul a membrane. Mainly a concern on bore and tank supplies, which are assessed before anything is quoted.

ADWG is the Australian Drinking Water Guidelines. Reference values describe drinking water in general. They are not test results for your home, and they are not performance claims for a Home Water system.

Net driving pressure

NDP = feed pressure − tank back-pressure − osmotic pressure

Production is roughly proportional to net driving pressure. As the tank fills, its back-pressure rises and production slows, which is why a tank-fed system never sustains its membrane's nominal rate.

Recovery

Recovery % = filtered water ÷ feed water × 100

The remainder is concentrate, sent to drain carrying the rejected salts. Tank-fed domestic units commonly send between 1 and 4 litres to drain for each litre produced. The ratio for the selected unit is confirmed from its specification.

Salt rejection

Rejection % = (1 − product TDS ÷ feed TDS) × 100

A TDS meter gives a quick indication that a membrane is working. It is not a contaminant test, and it is not a certified reduction claim.

Tank drawdown

Usable volume ≈ vessel volume × (1 − P precharge ÷ P shut-off)

Pressures are absolute: gauge pressure plus about 101 kPa. The shut-off valve typically closes when tank pressure reaches about two thirds of feed pressure, so a home with lower mains pressure stores less water in the same tank.

How a membrane separates
A reverse osmosis membrane is a thin-film composite with a dense polyamide layer. Water passes by diffusing through that layer under pressure, not by being sieved through holes, which is why it is described as far finer than any cartridge micron rating.
The first glass after standing
When a system sits idle, dissolved salts slowly diffuse across the resting membrane. The first water drawn afterwards can read higher on a TDS meter until fresh water is produced. This is known as TDS creep.
Low mineral water
Reverse osmosis lowers dissolved minerals along with other dissolved solids. Some systems add a remineralising post-filter. Whether one is fitted is confirmed with the selected system.
Rated is not delivered
Membrane ratings come from a test bench: a set temperature, pressure, recovery and test solution, with no tank attached. A household sees colder water, real mains pressure and a tank pushing back.

Output against water temperature

Feed waterTypical output
25 °C100% of rated output
20 °CAbout 85%
15 °CAbout 70%
10 °CAbout 60%

Typical temperature correction for thin-film membranes. The selected membrane's own correction table applies.

Under-sink installation

What goes in the cabinet.

Benchtop3-way mixer, in the existing tap position
Cold isolation valveFeeds the RO unit from the cold supply
RO unitSediment, carbon and membrane stages, mounted for front access
Storage tank8 L or 16 L nominal, positioned to suit the cabinet
Hot and cold to mixerStandard connections, as your current tap
Drain connectionConcentrate line to the sink waste
Power pointOnly for boosted or electronically controlled units
Indicative under-sink layout. The position of each part is set at assessment to suit your cabinet.

The RO unit and its storage tank sit in the cabinet under the kitchen sink. The unit takes cold water from an isolation valve, sends its concentrate to the sink waste, and feeds the RO channel of the 3-way mixer above.

Your existing kitchen mixer is removed and the 3-way mixer is fitted in its place. Where your kitchen suits, no additional drinking water tap or second benchtop hole is needed.

All installation work is completed by appropriately licensed plumbers.

  • Suitable mains water pressureAssessed
  • Under-sink cabinet clearanceAssessed
  • Cold water supply connectionAssessed
  • Wastewater drain connectionAssessed
  • Backflow protection where requiredAssessed
  • Pressure tank size and positionAssessed
  • Access for cartridge changesAssessed
  • Water treatment capacityAssessed
  • Wastewater and recovery ratioAssessed
  • Tap and benchtop compatibilityAssessed
  • Power, for boosted or electronic unitsAssessed
  • Licensed plumber, to AS/NZS 3500Assessed

Each item is reviewed at assessment, before a configuration is quoted.

Maintenance and filter replacement

Cartridges do the work. They need changing.

Sediment prefilterProtects the carbon and membrane from particles.
Carbon prefilterProtects the membrane from chlorine. Late changes shorten membrane life.
RO membraneLife depends on feed water quality and on prefilters being changed on time.
Post-treatmentWhere fitted, replaced on its own interval.
Storage tankPrecharge pressure checked at service.

Replacement intervals and cartridge prices are published once they are confirmed with the supplier. Whole-home cartridges are listed on the filters page.

Water quality and performance claims

What we will say, and what we will not.

Supported

  • Reverse osmosis is an established method of lowering total dissolved solids in drinking water
  • Carbon pretreatment is selected to help with chlorine related taste and odour
  • RO water is delivered through its own channel in the 3-way tap

Verified before we state it

  • Any contaminant reduction percentage, for the exact system supplied
  • NSF/ANSI 58 certification, if claimed, for the exact system supplied
  • WaterMark for the tap and RO unit, and WELS registration for the tap
  • Usable storage volume, membrane output and recovery ratio

Reverse osmosis

  • Does not remove every contaminant
  • Is not medically superior water
  • Is not boiling or chilled water
  • Serves the kitchen drinking water channel only, not the whole house

How we handle certification across the range is set out on the quality page.

Tap finishes

Proposed finishes.

Finishes are confirmed with the tap supplier before any are offered. Tell us your preference in the finder and your specialist will follow it up.

Installation requirements and FAQs

Is the reverse osmosis system available now?

RO Compact and RO Plus are proposed options. The supplier, components, compliance and installed price are still being confirmed. You can request a quote now and a specialist will tell you where things stand. Nothing is booked until the configuration is approved.

What is the difference between the 8 L and 16 L options?

The nominal size of the storage tank. Both use the same core filtration: sediment, carbon and a reverse osmosis membrane. The larger tank holds more filtered water between refills and needs more space under the sink.

Will I get the full 8 or 16 litres from the tank?

No. A pressure tank shares its volume between water and a cushion of compressed air, so the water you can draw is less than the nominal size. It depends on the tank, your mains pressure and the tank's precharge. We will publish usable volume once the manufacturer's figures are confirmed.

How fast does reverse osmosis make water?

That is set by the membrane, not the tank. A 50 GPD membrane is nominally rated at about 8 litres an hour and a 100 GPD membrane at about 16, under test conditions. Real output is lower in colder water, at lower pressure and as the tank fills.

Do I need a second tap on the bench?

Not where your kitchen suits. The 3-way mixer replaces your existing kitchen tap and carries hot, cold and RO water, with the RO water in its own internal channel.

Does reverse osmosis send water to drain?

Yes. The salts a membrane holds back are rinsed away in a concentrate stream, so every RO system needs a drain connection. How much goes to drain depends on the unit and your water pressure, and is confirmed from the selected system's specification.

Does it need power?

A conventional tank-fed system runs on mains pressure alone. Boosted or electronically controlled units need a power point under the sink. Which applies is confirmed at assessment.

Can I have RO and the boiling and chilled tap?

They are separate upgrades. If you ask for both, a specialist assesses compatibility in your kitchen first. We do not promise both through a single fixture.

Do I still need whole home filtration?

They do different jobs. Whole home filtration treats water for every tap, shower and appliance. Reverse osmosis treats drinking and cooking water at the kitchen sink.

How much does it cost installed?

Prices are not published until supplier and installation costs are approved. Your specialist confirms an installed price in writing.

Whole-home filtration for your house.
Reverse osmosis for your drinking water.

Pair your Home Water whole-home filtration system with premium reverse osmosis drinking water, delivered through a beautifully integrated kitchen mixer.